Nos disfrazamos de calabaza - Hasta 50%dto  Ver más

Enviar a
Montevideo, Montevideo
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Gewerbliche kühlung Systemhandbuch Für klimaanlagentechniker
Formato
Libro Físico
N° páginas
528
Encuadernación
Tapa Blanda
ISBN13
9798174196278

Gewerbliche kühlung Systemhandbuch Für klimaanlagentechniker

Stefan Müller;P. E. William H. Crawford (Autor) · Independently Published · Tapa Blanda

Gewerbliche kühlung Systemhandbuch Für klimaanlagentechniker - Stefan Müller;P. E. William H. Crawford

Libro Nuevo Importado
Envío: 14 a 19 días háb.
$ 3.789$ 2.084
-45%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan más de 100 unidades

$ 2.084
Llega entre el 16 Nov y el 23 Nov a Montevideo, Montevideo. Seleccionar ubicación

Reseña del libro "Gewerbliche kühlung Systemhandbuch Für klimaanlagentechniker"

Air conditioning work and commercial refrigeration share the same cycle, the same refrigerants and the same gauges. Everything else is different: the operating temperatures, the duty cycle, the controls standing between the thermostat and the compressor, the necessity of defrost, and the cost of being wrong. A comfort system that underperforms makes a building uncomfortable. A refrigeration system that underperforms destroys inventory overnight, quietly, while nobody is watching the box temperature.The system is also tightly coupled, which is what makes it hard. An undercharge and a restricted liquid line both read low on suction. Worn compressor valves and a fouled condenser both run hot. Reading one measurement in isolation produces confident, wrong conclusions. But because the effects propagate predictably, a small set of readings taken together forms a signature, and different faults produce different signatures.That is what this handbook teaches.Read suction pressure, discharge pressure, superheat and subcooling as one coupled pattern, not four separate numbersPredict what a healthy system should read under the current load and ambient, then measure against your predictionSeparate faults that share a symptom using compression ratio, condenser split and evaporator temperature differenceSet superheat on a zeotropic blend, where glide changes what the pressure is telling youTrace a fault through a live ladder circuit, series safeties and parallel operating controlsEvacuate to a genuine vacuum, confirm it with a decay test, and charge by the method the system calls forCalculate transmission, infiltration and product load, then reconcile it with what the system is actually doingSixteen chapters run from cycle thermodynamics and refrigerant properties through compressors, condensers, evaporators, metering devices, piping and oil return, electrical fundamentals, motors and drives, control circuits, defrost and safety controls, load calculation, service practice, systematic troubleshooting and commissioning. Each states its objectives, derives the theory step by step, and closes with worked examples and verified practice problems. Six appendices carry conversions, an equation reference, the field reading set, diagnostic quick-reference tables and blank service forms.Written for air conditioning technicians moving into commercial refrigeration, along with apprentices, journeymen, service contractors, facility maintenance staff and HVACR students working on walk-ins, reach-ins, display cases and rack systems.Open it at the troubleshooting chapter on your next call and work the reading set before you touch a component. Read more

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes